The only variant built to API 600 — if a specification says “gate valve to API 600”, this is the one to quote.

Why this variant

  • The only variant built to API 600 — if a specification says “gate valve to API 600”, this is the one to quote.
  • 2″–6″ (DN50–DN150) — check the size band before ordering.
  • 150 PSI at −29 to 425 °C, as published.
  • Cast steel ASTM A216 WCB — body, and what it will and will not stand.
  • Built to API 600, inspected and tested to API 598.
  • Stocked in Singapore & Malaysia — out within 24 hours.

ANSI 150 Cast Steel Gate Valve

ANSI 150# flange · API 600 · to 425 °C
In stock150 PSIAPI 600API 598

A rising-stem gate valve for isolation, with ANSI 150# flange ends, 2″–6″ (DN50–DN150), in Cast steel ASTM A216 WCB. Rated 150 PSI, built to API 600 and tested to API 598. Graphite packed — isolation duty only, never throttling.

Tell us the size, the fluid, pressure and temperature — quotes within 2 working hours.

EndsANSI 150# flange
Size2″–6″ (DN50–DN150)
BodyCast steel ASTM A216 WCB
Pressure150 PSI
Max temperature−29 to 425 °C
DesignAPI 600
InspectionAPI 598
StemRising stem, handwheel, multi-turn
PackingGraphite
⚠ Isolation only. Fully open or fully shut — never hold a gate valve part-open. Throttling on the gate face erodes gate and seat permanently, and a wrecked seat cannot be relied on to shut off. For throttling use a globe valve.

Construction

The ANSI 150 Cast Steel Gate Valve

Isolation duty, ANSI 150# flange ends, built to API 600.

A rising-stem gate valve in 2″–6″ (DN50–DN150), body in Cast steel ASTM A216 WCB, rated 150 PSI, inspected and tested to API 598. Fully open, the gate lifts clear of the bore and the valve presents almost no restriction and almost no pressure drop. That is what a gate valve is for.

The only variant built to API 600 — if a specification says “gate valve to API 600”, this is the one to quote.

⚠ Isolation only, never throttling

Held part-open, flow across the partly-raised gate vibrates it and erodes both gate and seat — permanently. Use a globe valve to regulate flow.

Graphite packing is what allows the heat

Metal-to-metal seating and a graphite-packed stem, rather than a PTFE seat. That is why gate valves take steam and hot oil where a ball valve stops at 150 °C.

Rated −29 to 425 °C

As published. We print the catalogue figure rather than inferring one from a sibling variant.

Rising stem, multi-turn

The stem travels up out of the bonnet as the valve opens, so it needs more headroom open than closed. Handwheel operated — not a quarter turn.

Tested to API 598

The one standard common to every variant in this range, which is what makes their test pressures directly comparable.

End connection: ANSI 150# flange

The end type is the first decision and cannot be changed later. Check it against the pipework, not the pressure rating — all ten variants compared.


Photographs

Three angles on the same valve

All photographs of the stocked item, not renders.

1. The valve as stocked

A rising-stem gate valve with the handwheel fitted. The stem you see above the bonnet is what travels as the valve opens — allow for it when you check headroom.

2. The body and the ends

The end connection is the first thing to check against your pipework, and the one thing that cannot be changed after ordering.

3. Bonnet and gland

Where the graphite packing sits. A small re-tighten of the gland after the first heat cycle is normal, not a fault.


Specification

Full specification

Everything that goes on a purchase order.

ItemDetail
Size range2″ to 6″ (DN50 to DN150)
End typeANSI 150# flange — to ASME B16.5
Body materialCast steel ASTM A216 WCB
Working pressure150 PSI
Maximum working temperature−29 °C to 425 °C
Design and manufactureAPI 600
Inspection and testAPI 598
Shell or body test3.1 MPa
Seal test2.2 MPa
Gas tightness test0.6 MPa
StemRising stem, handwheel operated, multi-turn
PackingGraphite
DutyIsolation only — never for throttling. For throttling use globe valves
StockSingapore & Malaysia warehouses — out within 24 hours

Dimensions

Sizes and dimensions — as printed

Millimetres. Face-to-face L is the gap the valve needs in the run; on a rising-stem gate valve you also need headroom above it, because the stem travels up as it opens.

SizePart noBore dFace-to-face LFlange OD DBolt circle D1Raised face D2Bolts n-d1CRF height f
2″VL-CS-GA-F-150-3251178150120.792.14-Ø1914.32
2 1/2″VL-CS-GA-F-150-4065190180139.7104.84-Ø1915.92
3″VL-CS-GA-F-150-4876203190152.41274-Ø1917.52
4″VL-CS-GA-F-150-64102229229190.51578-Ø1922.32
SizePart noBore dFace-to-face LOHandwheel WRBolts n-zKHeight HFlange thk tRF height f
5″VL-CS-GA-F-150-8012717815212092.18-Ø2230067622.32
6″VL-CS-GA-F-150-96152190178139104.88-Ø2230076623.92

⚠ Leave headroom, not just length

This is a rising stem: the stem travels up out of the bonnet as the valve opens, so the space it needs open is greater than its closed height. Check the clearance before fitting it under a platform or in a duct.

Face-to-face L is what decides whether it fits

Measure the gap in the run against it. On a replacement, measure the valve coming out rather than trusting a drawing — and remember a globe valve of the same size is longer.

Letters follow the manufacturer’s drawing

Where a letter is ambiguous or mislabelled in the catalogue we say so rather than guess at what was meant.

Support the weight

A valve must not hang on the pipework, and must never be used to pull a misaligned joint together.

Check the ends against the pipework, not the pressure

ANSI 150# flange — the end type is the first decision and cannot be changed after ordering.


Drawing

Sectional drawings — one per size band

Sectional drawing — ANSI 150 cast steel gate valve

DN50–DN100 (2″–4″) — 19 callouts, numbered 1 to 19.

Sectional drawing — ANSI 150 cast steel gate valve

DN125–DN150 (5″–6″) — a larger body, and the item numbers are not sequential: 10a, 10b, 19a, 19c, 20a, 20c and 17a all appear, as printed.

Callout numbers correspond to the item numbers in the parts lists below — one list per band.

Read the drawing with the tables

Callout numbers are the item numbers in the parts list, and the dimension letters are the column headings in the size table. Nothing on the drawing is named only there.

⚠ The two bands are not the same valve

The larger band has a different bonnet arrangement and a different parts list, which is why there are two drawings and two BOMs rather than one of each.

⚠ The catalogue test figures differ by band

The manufacturer sheet gives the body test as 3.0 MPa for 2″–4″ and 3.1 MPa for 5″–6″. Both are above, as printed.


Materials

Bill of materials

The manufacturer’s item numbers, so a spares order matches the parts list.

NoPart nameMaterial
1BodyASTM A216 WCB
2BonnetASTM A216 WCB
3WedgeASTM A216 WCB + 13%Cr
5SeatASTM A105 + 13%Cr
6StemASTM A182 F6a
10aPacking GlandASTM A276 410
10bGland FlangeASTM A216 WCB
17aGasketSS304 + Graphite
18PackingFlexible Graphite
19aBoltsASTM A193 B7
19cEye BoltsASTM A193 B7
20aNutsASTM A194 2H
20cNutsASTM A194 2H
23Back SeatASTM A276 410
26HandwheelASTM A47 32510
28Stem NutASTM B148 C95800
33PinASTM A29 1045
34Stem NutASTM B148 C95800
35CoverASTM A29 1025
36NutASTM A29 1025
NoPart nameMaterial
1BodyASTM A216 WCB
2BonnetASTM A216 WCB
3WedgeASTM A216 WCB + 13%Cr
5SeatASTM A105 + 13%Cr
6StemASTM A182 F6a
10aPacking GlandASTM A276 410
10bGland FlangeASTM A216 WCB
17aGasketSS304 + Graphite
18PackingFlexible Graphite
19aBoltsASTM A193 B7
19cEye BoltsASTM A193 B7
20aNutsASTM A194 2H
20cNutsASTM A194 2H
23Back SeatASTM A276 410
26HandwheelASTM A47 32510
28Stem NutASTM B148 C95800
33PinASTM A29 1045
34Stem NutASTM B148 C95800
35CoverASTM A29 1025
36NutASTM A29 1025

The item numbers are the manufacturer’s

They match the callouts on the sectional drawing, so a spares order matches the section rather than a description.

The seat and the gate faces are what wear

Everything else is a casting or a fastener. On an isolation valve those two surfaces take the duty every time it is closed.

Graphite packing is the reason for the temperature

It is also the part that beds in. A small re-tighten of the gland after the first heat cycle is normal.

The stem is worth asking about

A bent or scored stem is the usual reason a gate valve will not seat, and it is the part that moves furthest every cycle.

Published in full, not on request

If you need to know what touches your fluid, the whole list is above — we have not summarised it.


Test pressures

Test pressure and temperature

Factory proof tests. Not working pressures — the shell test proves the body, the seal test proves the gate against its seat. Do not design to them.

ItemValue
Normal Pressure150 PSI
Hydraulic Body Test3.0 MPa
Back Seal Test2.2 MPa
Seat Test2.2 MPa
Hermetical Seal Test0.6 MPa
Max Working Temperature−29 °C to 425°C
ItemValue
Normal Pressure150 PSI
Hydraulic Body Test3.1 MPa
Back Seal Test2.2 MPa
Seat Test2.2 MPa
Hermetical Seal Test0.6 MPa
Max Working Temperature−29 °C to 425°C

⚠ Do not design to these figures

The shell test proves the body and the seal test proves the gate against its seat. They are proof tests well above the working rating, and the valve is not intended to operate there.

The working rating is 150 PSI

That is the number to design to, at −29 to 425 °C.

API 598 is what makes these comparable

Every variant in this range is inspected and tested to it, so the figures on the other nine pages can be read against these directly.

⚠ What actually kills a gate valve is not pressure

It is being run part-open. Throttling on the gate face erodes gate and seat permanently, and a wrecked seat will not shut off when you need it.

Ask if you need the certificate

EN 10204 3.1 is available on request and the castings carry heat numbers — ask with the order, not after the goods arrive.


Selecting

Not sure this is the right one?

End type first, then the standard, then the material.

Choose this one when…

  • Your pipework takes ANSI 150# flange ends — checked, not assumed.
  • Your size falls in 2″–6″ (DN50–DN150).
  • Working pressure is within 150 PSI and temperature within −29 to 425 °C.
  • The duty suits Cast steel ASTM A216 WCB.
  • You need isolation, not flow control.

Choose something else when…

All ten side by side: the comparison table.


Catalogues

Official catalogue — direct download

ANSI 150 Cast Steel Gate Valve catalogue

AF Hydro — ANSI 150 Cast Steel Gate Valve

ANSI 150# flange · 2″–6″ · 150 PSI
PDFDownload →

FAQ

Frequently asked questions

What is the ANSI 150 Cast Steel Gate Valve for?

Isolation — fully open or fully shut. A rising-stem gate valve with ANSI 150# flange ends in 2″–6″ (DN50–DN150), body in Cast steel ASTM A216 WCB, rated 150 PSI, built to API 600 and tested to API 598. Fully open it presents almost no restriction and almost no pressure drop.

Can it be used to throttle flow?

No. Held part-open, flow across the partly-raised gate vibrates it and erodes both gate and seat — and the damage is permanent. A wrecked seat cannot be relied on to shut off. Use a globe valve to regulate flow.

What is the working temperature?

Rated −29 to 425 °C, as published. The packing is graphite and the seating is metal to metal, which is what allows the heat — a PTFE-seated ball valve stops at 150 °C.

What sizes are available?

2″–6″ (DN50–DN150). Part numbers, the bill of materials and the test pressures are all on this page, as printed in the catalogue.

How much headroom does it need?

More than its closed height. This is a rising stem: the stem travels up out of the bonnet as the valve opens. Check the clearance before fitting it under a platform or in a duct.

What about stock for Indonesia?

We hold it in our Singapore and Malaysia warehouses, out of the warehouse within 24 hours of PO. Quotes within 2 working hours.

Is it a globe valve or a gate valve I need?

A gate valve isolates: fully open or fully shut. A globe valve throttles — it is built to run part-open, which a gate valve is destroyed by. If the valve will ever be adjusted, it must be a globe valve. Note the globe is also longer face-to-face, so the two are not interchangeable in the run.

Which standards does it meet?

Designed and manufactured to API 600, and inspected and tested to API 598. API 598 is the common thread across all ten variants, which is what makes their test pressures directly comparable.

Can it be actuated?

It is handwheel operated and multi-turn, not quarter turn. Operating torque, the number of turns and any ISO 5211 pad are not published for this range — settle the actuation arrangement with us rather than assuming a top plate.

What is not published for this valve?

No Cv, no operating torque or turn count, no ISO 5211 pad, and no fire-safe certificate. EN 10204 3.1 certificates are available on request and the castings carry heat numbers. Anything the catalogue does not state we get from the factory rather than infer from a sibling variant.

Related: all gate valves · globe valves · ball valves · all low pressure valves

Other variants
ANSI 150 Cast Iron ANSI 150 Forged Steel ANSI 150 SS316 JIS 10K Cast Iron JIS 10K SS316 Threaded Forged Steel Threaded SS316 Threaded SS316 Socket Weld Forged Steel

Baca halaman ini dalam Bahasa Indonesia

Need prices? Send us your requirement list — answered within 2 working hours.

REQUEST A QUOTE
💬 Chat with us on WhatsApp